The Hickman County Finance Office will be accepting bids for a "Fire Alarm Monitoring/Service Repair and Equipment Replacement." This bid is for a multi-year contract covering fire alarm monitoring/service repair, and equipment replacement for Hickman County Schools. This bid will be system wide for all schools. The bid will be for a period of 3 years with a mutual two-year extension option. This bid will be good for the period of July 1, 2026 - June 30, 2029. All bidders must attach: A conflict-of-interest disclosure form can be obtained at https://ww.hickmank12.org/requestforproposal. Iran Divestment Act Certification Non-Boycott of Israel Certification TN business license A 1-million-dollar liability insurance certificate Workers compensation insurance Business license Background Acknowledgement Form Per TCA 49-5-406, all bidders' employees working on school properties must comply with all local, state, and federal laws. Sealed bids must be mailed or hand-delivered to the Hickman County Finance Office, 114 North Central Avenue, Suite 203, Centerville, TN 37033, and clearly marked on the outside of the envelope "Fire Alarm Monitoring/Service Repair and Equipment Replacement". Bids will be opened on May 26, 2026, at 10:00 a.m. in the Finance Office. The Hickman County Board of Education reserves the right to accept or reject any and all bids or parts of the bids and to waive any informalities that would prevent the acceptance of a better bid. Complete the bid on B (specs) and submit your bid on those forms. Specifications can be found at https://ww.hickmank12.org/requestforproposal. Or by calling 391-729-3391 Ext 3. Present Penny Rochelle 3) bids rec'd Minty cems Dlease see attached BA APR 3 O 2026 The Hickman County Finance Office will be accepting bids for a "Fire Alarm Monitoring/Service Repair and Equipment Replacement." This bid is for a multi-year contract covering fire alarm monitoring/service repair, and equipment replacement for Hickman County Schools. This bid will be system wide for all schools. The bid will be for a period of 3 years with a mutual two-year extension option. This bid will be good for the period of July 1, 2026 - June 30, 2029. All bidders must attach: A conflict-of-interest disclosure form can be obtained at https://ww.hickmank12.org/requestforproposal. Iran Divestment Act Certification Non-Boycott of Israel Certification TN business license A 1-million-dollar liability insurance certificate Workers compensation insurance Business license Background Acknowledgement Form Per TCA 49-5-406, all bidders' employees working on school properties must comply with all local, state, and federal laws. Sealed bids must be mailed or hand-delivered to the Hickman County Finance Office, 114 North Central Avenue, Suite 203, Centerville, TN 37033, and clearly marked on the outside of the envelope "Fire Alarm Monitoring/Service Repair and Equipment Replacement". Bids will be opened on May 26, 2026, at 10:00 a.m. in the Finance Office. The Hickman County Board of Education reserves the right to accept or reject any and all bids or parts of the bids and to waive any informalities that would prevent the acceptance of a better bid. Complete the bid on B (specs) and submit your bid on those forms. Specifications can be found at https://ww.hickmank12.org/requestforproposal. Or by calling 391-729-3391 Ext 3. NOTE: Please use this sheet to enter your bid figures and attach any necessary documents to the back of the bid sheet. SCOPE This bid is for the 2026/2027, 2027/2028, 2028/2029 school years with a mutual two-year extension option provided no increase in charges or costs during the 5 years bid period with an annual renewal contract letter of intent. SPECIFICATIONS Multi-Year Contract Requirements This bid is for a multi-year contract covering fire alarm monitoring, service repair, and equipment replacement for Hickman County Schools. All pricing submitted must remain firm for the entire five-year contract period. If, at any point during the contract term, the awarded vendor increases pricing for any reason, the contract shall be considered null and void, and the entire project will be rebid. 1 I Page Annual Fire Alarm Monitoring by School Fire Alarm Monitoring Services This bid covers the annual cost of monthly fire alarm monitoring for all eight (8) Hickman County School buildings. The facilities included in this service are: EHES- East Hickman Elementary School EHIS - East Hickman Intermediate School EHMS- East Hickman Middle School EHHS- East Hickman High School CES- Centerville Elementary School CIS - Centerville Intermediate School HCMS - Hickman County Middle School HCHS - Hickman County High School The awarded vendor shall provide continuous fire alarm monitoring services for each building and shall invoice the district annually for the full year of monthly monitoring services. All monitoring must meet applicable Fire Marshal requirements and comply with all state and local fire safety regulations. Annual Cost of Monthly Fire Alarm Monitoring $ $ 4800 2 I Page ANNUAL ALARM TESTING and CERTIFICATION SERVICING of ALARM EQUIPMENT and COMPONENTS At all eight schools, to be scheduled and finished by July 15th of each calendar year. This is to include a written check-off report in accordance with NFPA, to be provided for each school location's front office binder. A written hard copy of the report and service ticket should be left with each school's front office and hard copies sent to the Maintenance Director's office. Annual Fire Alarm Testing and Certification Service of Alarm Equipment and Components $ 10,000 3 I Page Installation of Communication Converter System for Fire Alarm Panel (One-time charge, applicable if upgrade is selected) Installation Furnish and install a UL-listed communicator and all required accessories, wiring, power supplies, antennas, and mounting hardware. All equipment shall be fully compatible with the existing fire alarm control panel and associated system components. Installation shall be performed in accordance with the manufacturer's instructions and industry best practices. Programming and Testing Program the communicator and associated fire alarm monitoring equipment to ensure proper operation and supervision. Verify successful transmission of all required alarm, supervisory, and trouble signals to the Monitoring Station. Conduct complete functional testing and provide confirmation that the monitoring system is operating correctly and reliably. Compliance All work shall comply with all applicable local, state, and national codes, including but not limited to: NFPA 72- National Fire Alarm and Signaling Code UL 864- Standard for Control Units and Accessories for Fire Alarm Systems Equipment shall be listed and approved for fire alarm service and monitoring applications. Documentation Provide test results, programming documentation, and verification of Monitoring Station communication upon completion. Coordinate all required inspections, testing, and acceptance documentation with the Authority Having Jurisdiction (AHJ) as applicable. 4 I Page Installation Labor Per Site EHES $ 100 EHIS $ 100 EHMS $ 100 EHHS $ 100 CES $ 100 CIS $ 100 HCMS $ 100 HCHS $ 100 Total Installation Cost $ 800 800 Equipment Cost Per Site EHES $ $ 200 EHIS $ 200 $ EHMS $ 200 EHHS $ 200 CES $ 200 CIS $ 200 HCMS $ 200 $ HCHS $ 200 $ Total Equipment Cost $ $ 1600 5 I Page COST of SERVICING REPAIR and/or REPLACEMENT of EQUIPMENT Service call trip charge is limited to one trip charge per trip to the same zip code. Multi trip charges will only be permitted if moving to a second zip code but not to a second location in the same zip code. Our zip codes for the 8 locations are Centerville Buildings 37033: CES, CIS, HCMS, HCHS and Lyles Buildings 37098: EHES, EHIS, EHMS, EHHS. Service Call Trip Charge $ 80 $ 100 extinguister or kitchen hard Hourly rate per tech $ $ 1,200 fire Alarm (normal rate) 150 Ex or hood / Hourly rate per tech $ $ - 300 fire Alarm (over-time rate) All parts exceeding $1,000.00 in cost must accompany the vendors' actual cost invoices incurred and attached with to billing invoices to ensure mark-ups are accurate and correct. Invoices without tickets will not be paid. Parts plus percentage of mark-up 30 % 6 I Page Annual Fire Extinguisher Inspections and Servicing This contract will allow for the bidding of the fire extinguishers to be checked off by location in each building and shall provide inspection, serviced by recharge, and/or replaced if beyond container life cycle and shall be annually retagged as prescribed in the Fire Marshals codes. Buildings are to be serviced 100% and accurately count all locations not missing any extinguishers. The service will be for all 11 locations in the school district to include all eight school buildings, HCHS B Building, Central Office Building, and Bus Garage. A hard copy of the checked-off inspections report by location shall be left with each location's front office and a hard copy to be sent to the Maintenance Director's office upon completion. At the bus garage there are spare extinguishers upstairs that are to be inspected, serviced, tagged and recharged and/or replaced as needed. There are extinguishers downstairs in the garage area for bus/vehicles that are annually serviced, tagged and recharged and/or replaced as needed. Location mapping and check-off sheets shall be the responsibility of the bidding vendor and not charged to HCBOE. NOTE: This agreement contract will require that the vendor return during the calendar year at no charge and tag & service any extinguishers that are missed at no cost to the owner, in the event they were not tagged during the inspections and found by the Maintenance and/or the Fire Marshall. Annual inspection fee per extinguisher one time re-tag by location $ 6.00 New extinguisher replacement cost per size $ Fire extinguisher recharge cost per size $ 5 lb -75 - 101b - k-class $ 210 - 70 - k class $ 180 7 I Page Fire Suppression Hoods: Bi-Annual Fire Suppression Hoods Kitchen Hood Suppression System Service Requirements The Hickman County Schools facilities are equipped with kitchen areas that include one or more fire-suppression hoods. The awarded vendor shall provide comprehensive annual servicing of all hood suppression systems in accordance with applicable codes and manufacturer specifications. As part of the annual service, the vendor is required to: 1. Inspect, test, and properly service all hood suppression systems located within each school facility. 2. Install new fusible links on every suppression hood as required on an annual basis. 3. Provide cleanup services in the event that a system discharges during inspection or testing. This includes the full cleanup and removal of any dry chemical agent discharged onto kitchen equipment or surrounding surfaces. All work must be performed by certified technicians and documented through detailed service reports provided to the district upon completion. Inspection Tagging and Compliance Requirements 1. Inspection Tagging Upon completion of each inspection, the awarded vendor shall affix the appropriate inspection tag or sticker to every hood suppression system. The tag must clearly display the date of inspection and any other information required by applicable fire codes. 2. Inspection Scheduling and Compliance All inspections must be performed within the timeframes prescribed by the Fire Marshal and all relevant fire safety codes. Inspections shall be completed on or up to two (2) days prior to the required due date. Under no circumstances may any inspection occur after the required due date. The awarded vendor is fully responsible for tracking and managing all required inspection intervals across all school kitchens. 3. Documentation and Reporting Requirements On the same day each inspection is completed, the vendor shall: 8 I Page Provide a copy of the inspection report directly to the kitchen manager before leaving the site, and Deliver a hard copy of the full inspection report to the Maintenance Director's office. All documentation must be complete, accurate, and compliant with all reporting standards established by the district and governing authorities. BiAnnual Manual Pull Station Tagging In addition to the annual hood suppression inspections and tagging requirements described above, the awarded vendor shall install a new biannual inspection tag on the manual suppression pull device located at each hood system. This tag must clearly indicate the inspection date and comply with all applicable fire safety and Fire Marshal code requirements. The vendor is responsible for ensuring all biannual tags remain current and are replaced on schedule. Suppression inspections are to be at the following kitchen locations: CES $ 220 CIS $ 220 HCMS $ 220 $ HCHS $ $ 220 EHES $ 220 EHIS $ 220 220 EHMS $ 220 EHHS $ 440 2 systems EHHS/VOCATIONAL CULINARY ARTS KITCHEN $ 220 Total amount for two (2) Bi-Annual Suppression Hood Inspections per year: $ 2,800 10 I Page Background Check Acknowledgement Form Contractor is required to meet al TCA 49-5-406, local, state, and federal laws regarding "workers on school properties." The Hickman County Board of Education further requires that no prior felons, drug offenders, or sexual registered offenders work on any school properties. Contractors will be required to wear contractor provided identification when on school premises. The contractor may be asked to provide proof of background check. Signature: 7 Mal Print: Tony MAllini - Title: Senior Account MANAger - Date: 5/20/26 - 11 I Page State of Tennessee Non-Boycott of Israel Certification The Bidder certifies that it is not currently engaged in and will not for the duration of the contract engage in a boycott of Israel as defined by Tenn. Code § 12-4-119. This provision shall not apply to contracts with a total value of less than two hundred fifty thousand dollars ($250,000) or to contractors with less than ten (10) employees. According to the law, a boycott of Israel means engaging in refusals to deal, terminating business activities, or other commercial actions that are intended to limit commercial relations with Israel, or companies doing business in or with Israel or authorized by, licensed by, or organized under the laws of the State of Israel to do business, or persons or entities doing business in Israel, when such actions are taken: 1. In compliance with, or adherence to, calls for a boycott of Israel, or 2. In a manner that discriminates on the basis of nationality, national origin, religion, or other unreasonable basis, and is not based on a valid business reason. Tenn. Code § 12-4-119 Signature: 7 Mal Print: Tony Mallini - Date: 5-20-26 12 I Page IRAN DIVESTMENT ACT CERTIFICATION I understand that under the Iran Divestment Act, T.C.A. 12-12-101 - 12-12-113, political subdivisions in Tennessee are prohibited from entering into any procurement or contract over $1,000 with a person who engages in investment activities in Iran. The state's chief procurement officer, as required by T.C.A. 12-12-106, has created a list of persons who engage in investment activities in Iran. Any person who is on the list is ineligible to contract with any political subdivision of the State of Tennessee, and any such contract will be considered void under T.C.A. 12-12-110. The list is published on the Tennessee Department of General Services' website at: https://www.tn.gov/content/dam/tn/generalservices/documents/cpo/library/c po-library/public-information- library/List of persons pursuant to Tenn. Code Ann. 12-12- 106 Iran Divestment Act updated with NY06-07-23.pdf CERTIFICATION By submission of this bid, each bidder and each person signing on behalf of any bidder certifies, and in the case of a joint bid each party thereto certifies as to its own organization, under penalty of perjury, that to the best of its knowledge and belief that each bidder is not on the list created pursuant to T.C.A 12-12-106. Bidder Name: State Systems, INC Tony Mallin, Bidder Signature: 7 Mul 5/20/26 Date: 12 I Page Hickman County Government Conflict of Interest Disclosure Form The County Financial Management System of 1981 contains the most stringent conflict of interest provisions. TCA $5-21-121 provides: (a) The director, purchasing agent, members of the committee, members of the county legislative body or other officials, employees, or members of the board of education or highway commission shall not be financially interested or have any personal beneficial interest, either directly or indirectly, in the purchase of any supplies, materials, equipment or contractual services for the county. (b) No firm, corporation, partnership, association or individual furnishing any such supplies, materials, equipment or contractual services, shall give or offer, nor shall the director or purchasing agent or any assistant or employee accept or receive directly or indirectly from any person, firm, corporation, partnership or association to whom any contract may be awarded, by rebate, gift or other otherwise, any money or other things of value whatsoever, or any promise, obligation or contract for future reward or compensation. Date: 5/20/26 Name: TONY MAlliN. Please describe below any relationships, transactions, positions you hold (volunteer or otherwise), or circumstances that you believe could contribute to a conflict of interest: I have no conflict of interest to report. I have the following conflict of interest to report (please specify any boards or committees you (and/or your spouse) sit on, the name of your employer and any businesses you or your spouse may own. I hereby certify that the information set forth above is true and complete to the best of my knowledge. Date: 5/20/26 7Ml Signature: 13 I Page ACORD® DATE (MM/DD/YYYY) CERTIFICATE OF LIABILITY INSURANCE 8/1/2026 3/20/2026 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). CONTACT PRODUCER Lockton Companies, LLC NAME: DBA Lockton Insurance Brokers, LLC in CA PHONE FAX (A/C. No. Ext): (A/C, No): CA license #0F15767 E-MAIL ADDRESS: 3280 Peachtree Rd. NE, Ste. 1000 INSURER(S) AFFORDING COVERAGE NAIC # Atlanta GA 30305 INSURER A: Hudson Excess Insurance Company 14484 (404) 460-3600 INSURED INSURER B : The Travelers Indemnity Company 25658 State Systems LLC 1551530 1861 Vanderhorn Dr INSURER C : The Charter Oak Fire Insurance Company 25615 Memphis TN 38134 INSURER D : Travelers Property Casualty Company of America 25674 INSURER E : Westchester Surplus Lines Insurance Co 10172 INSURER F : COVERAGES CERTIFICATE NUMBER: 23179830 REVISION NUMBER: XXXXXXX THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN is SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES, LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MM/DD/YYYY) (MM/DD/YYYY) LIMITS COMMERCIAL GENERAL LIABILITY A N N ALM10130-00 2/7/2026 8/1/2026 EACH OCCURRENCE $ 1,000,000 DAMAGE TO RENTED CLAIMS-MADE OCCUR PREMISES (Ea occurrence) $ 500,000 MED EXP (Any one person) $ 10,000 PERSONAL & ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 5,000,000 POLICY PRO- LOC PRODUCTS-COMP/OP AGG $ 2,000,000 JECT $ OTHER: COMBINED SINGLE LIMIT B AUTOMOBILE LIABILITY N N DT-810-A8126919-IND-26 2/7/2026 2/7/2027 (Ea accident) $ 1,000,000 ANY AUTO BODILY INJURY (Per person) $ XXXXXXX OWNED SCHEDULED BODILY INJURY (Per accident) $ XXXXXXX AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ XXXXXXX AUTOS ONLY AUTOS ONLY (Per accident) $ XXXXXXX A UMBRELLA LIAB OCCUR N N ALMU10056-00 2/7/2026 8/1/2026 EACH OCCURRENCE $ 5,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $ 5,000,000 DED RETENTION $ 10,000 $ XXXXXXX PER OTH- WORKERS COMPENSATION N C 2/7/2026 2/7/2027 AND EMPLOYERS' LIABILITY UB-A8090273-26-26-G STATUTE ER Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE E.L. EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER-EXCLUDED? N N/A (Mandatory In NH) E.L. DISEASE- EA EMPLOYEE $ 1,000,000 If yes, describe under E.L. DISEASE- POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS below A Prof/Poll N N ALM10130-00 2/7/2026 8/1/2026 Limits: Included/$1M D Leased/Rented Equip QT-630-A8150089-TIL-26 2/7/2026 2/7/2027 Limits: $250K E Fress G4878947A 001 2/7/2026 8/1/2026 Fac Occ $5M ! A.gg $5M DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION See Attachments SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 23179830 ACCORDANCE WITH THE POLICY PROVISIONS. State Systems Inc. 1861 Vanderhorn Drive AUTHORIZED REPRESENTATIVE Memphis TN 38134 Khigler © 1988-2013 ACORD CORPORATION. All rights reserve STATE OF TENNESSEE DEPARTMENT OF COMMERCE AND INSURANCE STATE SYSTEMS, LLC ID NUMBER: 2508 LIC STATUS ACTIVE EXPIRATION DATE: July 31, 2026 ALARM SYSTEMS CONTRACTORS BOARD ALARM CONTRACTING COMPANY THIS is TO CERTIFY THAT ALL REQUIREMENTS OF THE STATE OF TENNESSEE HAVE BEEN MET 11398 ATTN:ROBERT MCBRIDE STATE SYSTEMS, LLC 1861 VANDERHORN DR MEMPHIS, TN 38134 14012338 State of Cennessee ALARM SYSTEMS CONTRACTORS BOARD ALARM CONTRACTING COMPANY STATE SYSTEMS, LLC ROBERT GRAHAM MCBRIDE This is to certify that all requirements of the State of Tennessee have been met. OF THE STATEOF OF ID NUMBER: 2508 LIC STATUS: ACTIVE EXPIRATION DATE: July 31, 2026 FLORIDA AGRICULTURE 7796 J FIRE CCTV BURGL IR VOID IN-1313 DEPARTMENT OF COMMERCE AND INSURANCE VOID VOID MA STATE OF TENNESSEE DEPARTMENT OF COMMERCE AND INSURANCE STATE SYSTEMS, INC. 434137 ID NUMBER: 40841 LIC STATUS: ACTIVE EXPIRATION DATE: November 30, 2027 BOARD FOR LICENSING CONTRACTORS CONTRACTOR THIS IS TO CERTIFY THAT ALL REQUIREMENTS OF THE STATE OF TENNESSEE HAVE BEEN MET STATE SYSTEMS, INC. 1861 VANDERHORN DRIVE MEMPHIS, TN 38134 434137 State of Tennessee BOARD FOR LICENSING CONTRACTORS CONTRACTOR STATE SYSTEMS, INC. This is to certify that all requirements of the State of Tennessee have been met. ID NUMBER: 40841 EXPIRATION DATE: November 30, 2027 STATE GREAT THE AGRICULTURE OMMERC XVI F THE STATES LIC STATUS: ACTIVE UNLIMITED; CE-D; CE-F; CE-G; CMC; MU-A 7796 IN-1313 DEPARTMENT OF COMMERCE AND INSURANCE AMERICAN FIRE PROTECTION ® GROUP, INC. Attn: Hickman Co. Finance RFP Response For: "Fire Alarm Monitoring/Service Repairs and Equipment Replacement" 114 N Central Ave, Ste 203 Centerville, TN 37033 May 22, 2026 American Fire Protection Group, Inc. Strong Values, Exceptional Results The Hickman County Finance Office will be accepting bids for a "Fire Alarm Monitoring/Service Repair and Equipment Replacement." This bid is for a multi-year contract covering fire alarm monitoring/service repair, and equipment replacement for Hickman County Schools. This bid will be system wide for all schools. The bid will be for a period of 3 years with a mutual two-year extension option. This bid will be good for the period of July 1, 2026 - June 30, 2029. All bidders must attach: A conflict-of-interest disclosure form can be obtained at https://ww.hickmank12.org/requestforproposal. Iran Divestment Act Certification Non-Boycott of Israel Certification TN business license A 1-million-dollar liability insurance certificate Workers compensation insurance Business license Background Acknowledgement Form Per TCA 49-5-406, all bidders' employees working on school properties must comply with all local, state, and federal laws. Sealed bids must be mailed or hand-delivered to the Hickman County Finance Office, 114 North Central Avenue, Suite 203, Centerville, TN 37033, and clearly marked on the outside of the envelope "Fire Alarm Monitoring/Service Repair and Equipment Replacement". Bids will be opened on May 26, 2026, at 10:00 a.m. in the Finance Office. The Hickman County Board of Education reserves the right to accept or reject any and all bids or parts of the bids and to waive any informalities that would prevent the acceptance of a better bid. Complete the bid on B (specs) and submit your bid on those forms. Specifications can be found at https://ww.hickmank12.org/requestforproposal. Or by calling 391-729-3391 Ext 3. Annual Fire Alarm Monitoring by School Fire Alarm Monitoring Services This bid covers the annual cost of monthly fire alarm monitoring for all eight (8) Hickman County School buildings. The facilities included in this service are: EHES- East Hickman Elementary School EHIS - East Hickman Intermediate School EHMS - East Hickman Middle School EHHS- East Hickman High School CES- Centerville Elementary School CIS - Centerville Intermediate School HCMS - Hickman County Middle School HCHS - Hickman County High School The awarded vendor shall provide continuous fire alarm monitoring services for each building and shall invoice the district annually for the full year of monthly monitoring services. All monitoring must meet applicable Fire Marshal requirements and comply with all state and local fire safety regulations. Annual Cost of Monthly Fire Alarm Monitoring $ 4,320.00 (all 8 sites combined, per year) 21 Installation of Communication Converter System for Fire Alarm Panel (One-time charge, applicable if upgrade is selected) Installation Furnish and install a UL-listed communicator and all required accessories, wiring, power supplies, antennas, and mounting hardware. All equipment shall be fully compatible with the existing fire alarm control panel and associated system components. Installation shall be performed in accordance with the manufacturer's instructions and industry best practices. Programming and Testing Program the communicator and associated fire alarm monitoring equipment to ensure proper operation and supervision. Verify successful transmission of all required alarm, supervisory, and trouble signals to the Monitoring Station. Conduct complete functional testing and provide confirmation that the monitoring system is operating correctly and reliably. Compliance All work shall comply with all applicable local, state, and national codes, including but not limited to: NFPA 72 - National Fire Alarm and Signaling Code UL 864 - Standard for Control Units and Accessories for Fire Alarm Systems Equipment shall be listed and approved for fire alarm service and monitoring applications. Documentation Provide test results, programming documentation, and verification of Monitoring Station communication upon completion. Coordinate all required inspections, testing, and acceptance documentation with the Authority Having Jurisdiction (AHJ) as applicable. 4 I Page COST of SERVICING REPAIR and/or REPLACEMENT of EQUIPMENT Service call trip charge is limited to one trip charge per trip to the same zip code. Multi trip charges will only be permitted if moving to a second zip code but not to a second location in the same zip code. Our zip codes for the 8 locations are Centerville Buildings 37033: CES, CIS, HCMS, HCHS and Lyles Buildings 37098: EHES, EHIS, EHMS, EHHS. Service Call Trip Charge $ 100.00 Hourly rate per tech $ 140.00 (normal rate) Hourly rate per tech $ 210.00 (over-time rate) All parts exceeding $1,000.00 in cost must accompany the vendors' actual cost invoices incurred and attached with to billing invoices to ensure mark-ups are accurate and correct. Invoices without tickets will not be paid. Parts plus percentage of mark-up 50 % 6|Page Fire Suppression Hoods: Bi-Annual Fire Suppression Hoods Kitchen Hood Suppression System Service Requirements The Hickman County Schools facilities are equipped with kitchen areas that include one or more fire-suppression hoods. The awarded vendor shall provide comprehensive annual servicing of all hood suppression systems in accordance with applicable codes and manufacturer specifications. As part of the annual service, the vendor is required to: 1. Inspect, test, and properly service all hood suppression systems located within each school facility. 2. Install new fusible links on every suppression hood as required on an annual basis. 3. Provide cleanup services in the event that a system discharges during inspection or testing. This includes the full cleanup and removal of any dry chemical agent discharged onto kitchen equipment or surrounding surfaces. All work must be performed by certified technicians and documented through detailed service reports provided to the district upon completion. Inspection Tagging and Compliance Requirements 1. Inspection Tagging Upon completion of each inspection, the awarded vendor shall affix the appropriate inspection tag or sticker to every hood suppression system. The tag must clearly display the date of inspection and any other information required by applicable fire codes. 2. Inspection Scheduling and Compliance All inspections must be performed within the timeframes prescribed by the Fire Marshal and all relevant fire safety codes. Inspections shall be completed on or up to two (2) days prior to the required due date. Under no circumstances may any inspection occur after the required due date. The awarded vendor is fully responsible for tracking and managing all required inspection intervals across all school kitchens. 3. Documentation and Reporting Requirements On the same day each inspection is completed, the vendor shall: 8 Page Background Check Acknowledgement Form Contractor is required to meet al TCA 49-5-406, local, state, and federal laws regarding "workers on school properties." The Hickman County Board of Education further requires that no prior felons, drug offenders, or sexual registered offenders work on any school properties. Contractors will be required to wear contractor provided identification when on school premises. The contractor may be asked to provide proof of background check. Signature: Junifer mcmula Print: Jennifer McMullin Title: Special Hazards, Alarm & Detection Sales Date: 5/22/2026 10 I Page IRAN DIVESTMENT ACT CERTIFICATION I understand that under the Iran Divestment Act, T.C.A. 12-12-101 - 12-12-113, political subdivisions in Tennessee are prohibited from entering into any procurement or contract over $1,000 with a person who engages in investment activities in Iran. The state's chief procurement officer, as required by T.C.A. 12-12-106, has created a list of persons who engage in investment activities in Iran. Any person who is on the list is ineligible to contract with any political subdivision of the State of Tennessee, and any such contract will be considered void under T.C.A. 12-12-110. The list is published on the Tennessee Department of General Services' website at: https://www.tn.gov/content/dam/tn/generalservices/documents/cpo/librar/0 po-library/public-information- library/List of persons pursuant to Tenn. Code Ann. 12-12- 106 Iran Divestment Act updated with NY06-07-23. pdf CERTIFICATION By submission of this bid, each bidder and each person signing on behalf of any bidder certifies, and in the case of a joint bid each party thereto certifies as to its own organization, under penalty of perjury, that to the best of its knowledge and belief that each bidder is not on the list created pursuant to T.C.A 12-12-106. Bidder Name: Jennifer McMullin, American Fire Protection Group Bidder Signature: Jennifer mcmall Date: 5/22/2026 12 AMERICAN Fire Extinguisher Inspection List FIRE PROTECTION GROUP, INC. Location Code: Contact: Company: American Fire Protection Group Contact Address: Address: 155 North Conalco Drive Jackson, TN 38301 Phone: Company Phone: 731-424-0310 Email: Inspector: Cody Holland 2055 TN Portable Fire Ext Property Evaluated: Date of Work: Frequency: Annual Description: Fire Extinguishers Work Order: Deficio cy Sundary Status: Open Fire extinguisher deficiency for Tag # 8, Serial Number: K-88321 Model: Ansu AA Size: 10#, Type: ABC. 6yr due Status: Open Fire extinguisher deficiency for Tag # 14, Serial Number: E-83203600, Model: Sentry AA10S, Size: 10#, Type: ABC. 6yr due Status: Open Fire extinguisher deficiency for Tag # 16, Serial Number: E-72508148, Model: Sentry AA10S, Size: 10#, Type: ABC. 6yr due Service Summary American Fire Protection Group, 155 North Conalco Drive, Jackson, TN, 38301 Phone: 731-424-0310 Page 1 of 4 AMERICAN American Fire Protection Group 155 North Conalco Drive FIRE PROTECTION Jackson, TN 38301 GROUP, INC. Phone: 731-424-0310 Fire Extinguisher Inspection List Account Information Facility Name: Property Type: Location Code: Service Address: Owner: Owner's Phone: Owner's Address: Zone: 1 Zone: 1 Tag Serial Number Model Size Type Location La Servi ext Service Frequency Inspection Comments 1 C-99119847 SimplexGrinnell 10# ABC Right dock entrance, yı 024 Hydro 2030 Annual Pass (2017) AA10s breakroom 2 C9911988 SimplexGrinnell 10# ABC Pole #1 in from f 6)20. Hydro 2030 Annual Pass (2017) AA10s breaknom 3 I51719087 Badger (2025) 10# ABC 2nd pole throms New 2025 6 yr 2031 Annual Pass ADV-10MP-1 4 C-99119899 SimplexGrinnell 10# ABC Bac wan behind 6 yr 2024 Hydro 2030 Annual Pass (2017) AA10s poy dercoat. 5 H22617059 Badger (2023) 10# ABC 3rd pole down in front of New 2023 6 yr 2029 Annual Pass ADV-10 office 6 C-99119836 SimplexGrinnell 10# ABC 2nd door by loading 6 yr 2024 Hydro 2030 Annual Pass (2017) AA10S dock 7 H22617054 Badger (2023) 10# ABC Inside office New 2023 6 yr 2029 Annual Pass ADV-10 8 K-883213 Ansul (2011) 10# ABC Loading area New 2018 6 yr 2024 Annual Fail 6yr due AA105 9 C-99119841 SimplexGrinnell 10# ABC Middle pole in loading 6 yr 2024 Hydro 2030 Annual Pass (2017) AA10S area 10 C-99119853 SimplexGrinnell 10# ABC Exit door by dock 6 yr 2024 Hydro 2030 Annual Pass (2017) AA10S 11 E-83203601 Sentry (2018) 10# ABC Pole 7 in front of dock 6 yr 2024 Hydro 2030 Annual Pass AA10S 12 H-09109074 Sentry (2022) 10# ABC Pole by welding area, 6 yr 2024 Hydro 2030 Annual Pass AA10S beside rack 13 C-99119898 SimplexGrinnell 10# ABC Back wall welding area 6 yr 2024 Hydro 2030 Annual Pass (2017) AA10S #1 © FormLink Systems, Inc., Fire Extinguisher 2.1 Page 3 of 4 AMERICAN Fire Alarm Inspection and Testing Report FIRE PROTECTION GROUP, INC. Location Code: Contact: Company: American Fire Protection Group Address: 155 North Conalco Drive Contact Address: Jackson, TN 38301 Company Phone: 731-424-0310 Phone: Inspector: Cody Holland Email: 50454 TN Fire Alarm Date of Work: 12/4/2025 Frequency: Annual Tag: Green Property Evaluated: Description: Fire Alarm and Devices (Fire Alarm Inspection) Work Order: mple ficiency Summary There are ne rep tted deficiencies for this submission General Comments These items are outside the regular scope of the required inspection and are not the result of an engineering review. This information is not intended to be all- inclusive but rather a list of items discovered as a by-product of the required inspection. There are no general comments for this submission American Fire Protection Group, 155 North Conalco Drive, Jackson, TN, 38301 Phone: 731-424-0310 Page 1 of 7 American Fire Protection Group AMERICAN 155 North Conalco Drive FIRE PROTECTION Jackson, TN 38301 GROUP. INC. Phone: 731-424-0310 Power Supplies Control Unit Manufacturer: Model Number: Location: Disconnecting Location: Notifier Fcps-24s8 Nurse station 2 Mech room Battery 1 Load Test Voltage: Amps: Mfr Year: VDC: Ah: Charger Result of Battery 1 & 2 12 7 2023 Battery 1 13.54 5.39 Voltage: 14.74 Battery 2 Load Test Voltage: Amps: Mfr Year: VDC: Ah: Charger Battery 2 Voltage: Pass Fail Replaced 12 7 2023 13.92 4.60 13.74 5. Testing Results 5.1 Control Unit and Related Equipment Description Visual Inspection Functional Test Results Control unit Yes No Yes No Pass Fail N/A Lamps / LEDs / LCDs Yes No Yes No Pass Fail N/A Fuses Yes No Yes No Pass Fail N/A Trouble signals Yes No Yes No Pass Fail N/A Disconnect switches Yes No Yes No Pass Fail N/A Ground-fault monitoring Yes No Yes No Pass Fail N/A Supervision Yes No Y Pass Fail N/A Annunciators Yes No Ye. No Pass Fail N/A Remote power panels Yes No No Pass Fail N/A Other Yes No Y No Pass Fail N/A 5.2 Secondary Power Description Visual Inspection Functional Test Results Battery condition Yes No Yes No Pass Fail N/A Load voltage Yes No Yes No Pass Fail N/A Discharge test Yes No Yes No Pass Fail N/A Charger test Yes No Yes No Pass Fail N/A Remote panel batteries Yes No Yes No Pass Fail N/A 5.3 Notification Appliances Include Notification Appliances Table on this Report? Yes No Notification Appliances Appliance Type # Installed # Tested Test Results Bell(s) 0 0 Pass Fail N/A Horn(s) 0 0 Pass Fail N/A Horn/Strobe(s) 17 17 Pass Fail N/A Mini Horn(s) 0 0 Pass Fail N/A Speaker(s) 0 0 Pass Fail N/A Speaker/Strobe(s) 0 0 Pass Fail N/A Strobe(s) 0 0 Pass Fail N/A 5.4 Interface Equipment Complete supplementary interface component test form for all interface components. Circuit Interface / Signaling Line Circuit Interface / Fire Alarm Control Interface American Fire Protection Group, 155 North Conalco Drive, Jackson, TN, 38301 Phone: 731-424-0310 Page 3 of 7 American Fire Protection Group AMERICAN 155 North Conalco Drive FIRE PROTECTION Jackson, TN 38301 GROUP, INC. Phone: 731-424-0310 Zone: 1 Asset Address Location Notes Frequenc Last Test Comments Type y Tested Results TS Backflow bottom Annual 12/4/2025 Pass TS Backflow top Annual 12/4/2025 Pass TS Riser room Annual 12/4/2025 Pass WF Riser room Annual 12/4/2025 Pass WF Wet riser Annual 12/4/2025 Pass Zone: Main Zone: Main Asset Address Location Notes Frequenc Last Test Comments Type y Tested Results DH 00269159 At rm 108 Annual 12/4/2025 Pass DH 00269148 At rm 118 Annual 12/4/2025 Pass DH 00269149 At rm 118 Annual 12/4/2025 Pass DH 00269168 At mm 203 Annual 12/4/2025 Pass DH 00269169 At rm 203 Annual 12/4/2025 Pass SD 00269175 At rm 207 Annu 12/4/2025 Pass DH 00269085 At rm 309 Ann al /4/2025 Pass DH 00269086 At rm 309 nu /4/2025 Pass SD 00269096 At m 326 12/4/2025 Pass DH 00269097 At mm 401 nual 12/4/2025 Pass DH 00269099 At rm 401 nual 12/4/2025 Pass SD 00269101 At rm 409 Annual 12/4/2025 Pass DH 00269107 At rm 410 Annual 12/4/2025 Pass DH 00269108 At rm 410 Annual 12/4/2025 Pass PS 00269105 At mm 410 Annual 12/4/2025 Pass DH 00269178 At room 209 Annual 12/4/2025 Pass DH 00269179 At room 209 Annual 12/4/2025 Pass DH 00269087 At room 309 Annual 12/4/2025 Pass DH 00269088 At room 309 Annual 12/4/2025 Pass SD 00269076 By room 219 Annual 12/4/2025 Pass SD 00269077 By room 223 Annual 12/4/2025 Pass DD 00269121 Dining area ceiling Annual 12/4/2025 Pass DD 00269122 Dining area ceiling Annual 12/4/2025 Pass SD 00269186 Dining rm Annual 12/4/2025 Pass SD 00269188 Dining rm Annual 12/4/2025 Pass DD 00269126 Dining room Annual 12/4/2025 Pass DD 00269127 Dining room Annual 12/4/2025 Pass PS 00269189 Dining room exit Annual 12/4/2025 Pass HD 00269190 Dining room storage Annual 12/4/2025 Pass PS 00269161 Front door Annual 12/4/2025 Pass HD 00269187 In dining room Annual 12/4/2025 Pass SD 00269136 In laundry Annual 12/4/2025 Pass HD 00269135 In laundry room Annual 12/4/2025 Pass DD In the hall outside of 00269144 activities, supply Annual 12/4/2025 Pass room HD 00269131 In the kitchen Annual 12/4/2025 Pass HD 00269132 In the kitchen Annual 12/4/2025 Pass HD 00269134 In the kitchen Annual 12/4/2025 Pass SD 00269075 Nurses station 2 Annual 12/4/2025 Pass American Fire Protection Group, 155 North Conalco Drive, Jackson, TN, 38301 Phone: 731-424-0310 Page 5 of 7 American Fire Protection Group AMERICAN 155 North Conalco Drive FIRE PROTECTION Jackson, TN 38301 GROUP, INC. Phone: 731-424-0310 Zone: Main Asset Address Location Notes Frequenc Last Test Comments Type y Tested Results SD 00269146 SD 35 Annual 12/4/2025 Pass SD 00269142 SD 37 Annual 12/4/2025 Pass SD 00269139 SD 39 Annual 12/4/2025 Pass SD 00269119 SD 41 Annual 12/4/2025 Pass SD 00269130 SD 43 Annual 12/4/2025 Pass SD 00269125 SD 44 Annual 12/4/2025 Pass SD 00269129 SD 46 Annual 12/4/2025 Pass PS 00269112 Serinity rm Annual 12/4/2025 Pass SD 00269120 Vending machine Annual 12/4/2025 Pass 6. Notifications That Testing Is Complete Contact Time Monitoring organization: AFPG 10:00 Building management: Maintenance 10:00 7. System Restored To Normal Operation Date: 12/4/2025 Time: 10:00 8. Observations These items are outside the regular scope of the required inspection nd an not result of an engineering review. This information is not intended to be all-inclusive but rather a list of items discovered as a by-prom of the quir inspection. Please see the summary section at the top of the form for the co ments. 9. Inspector Information: Test Verification: Inspected By Cody Holland Inspector Signature C'Jall Inspector License: 50454 TN Fire Alarm Date of Work 12/4/2025 Inspection Notes Owner's Section Is the Owner or a representative available? Yes No owner available onsite American Fire Protection Group, 155 North Conalco Drive, Jackson, TN, 38301 Phone: 731-424-0310 Page 7 of 7 AMERICAN Suppression Hood Inspection and Testing Report FIRE PROTECTION ® GROUP, INC. Location Code: Contact: Company: American Fire Protection Group Contact Address: Address: 155 North Conalco Drive Jackson, TN 38301 Phone: Company Phone: 731-424-0310 Email: Inspector: Brian Johnson 1960 Port/Fixed Ext. Date of Work: 9/16/2025 Frequency: Annual Property Evaluated: Tag: Green Description: Hood (Hood Inspection) Work Order: Deficie cy m nary There are no repo ed den encies for this submission Ge al Comments These items are outside the regular scope of the spec in and are not the result of an engineering review. This information is not intended to be all- inclusive but rather a list of items discovered as a by-product of he required inspection. There are no general comments for this submission American Fire Protection Group, 155 North Conalco Drive, Jackson, TN, 38301 Phone: 731-424-0310 Page 1 of 3 American Fire Protection Group AMERICAN 155 North Conalco Drive FIRE PROTECTION Jackson, TN 38301 GROUP, INC. Phone: 731-424-0310 Title Maintenance Date 9/16/2025 Inspected By Brian Johnson Inspector Signature L4/ Inspector License: 1960 Port/Fixed Ext. Date of Work 9/16/2025 Observations These items are outside the regular scope of the required inspection and are not the result of an engineering review. This information is not intended to be all-inclusive but rather a list of items discovered as a by-product of the required inspection. Sample American Fire Protection Group, 155 North Conalco Drive, Jackson, TN, 38301 Phone: 731-424-0310 Page 3 of 3 Hickman County Government Conflict of Interest Disclosure Form The County Financial Management System of 1981 contains the most stringent conflict of interest provisions. TCA $5-21-121 provides: (a) The director, purchasing agent, members of the committee, members of the county legislative body or other officials, employees, or members of the board of education or highway commission shall not be financially interested or have any personal beneficial interest, either directly or indirectly, in the purchase of any supplies, materials, equipment or contractual services for the county. (b) No firm, corporation, partnership, association or individual furnishing any such supplies, materials, equipment or contractual services, shall give or offer, nor shall the director or purchasing agent or any assistant or employee accept or receive directly or indirectly from any person, firm, corporation, partnership or association to whom any contract may be awarded, by rebate, gift or other otherwise, any money or other things of value whatsoever, or any promise, obligation or contract for future reward or compensation. Date: 5/26/26 Name: RICHARD EVERETT MANAGER, ACTIVE ENERGY SERVICESCE Please describe below any relationships, transactions, positions you hold (volunteer or otherwise), or circumstances that you believe could contribute to a conflict of interest: I have no conflict of interest to report. I have the following conflict of interest to report (please specify any boards or committees you (and/or your spouse) sit on, the name of your employer and any businesses you or your spouse may own. I hereby certify that the information set forth above is true and complete to the best of my knowledge. Date: 5/26/26 Signature: Rhnu IRAN DIVESTMENT ACT CERTIFICATION I understand that under the Iran Divestment Act, T.C.A. 12-12-101- 12-12-113, political subdivisions in Tennessee are prohibited from entering into any procurement or contract over $1,000 with a person who engages in investment activities in Iran. The state's chief procurement officer, as required by T.C.A. 12-12-106, has created a list of persons who engage in investment activities in Iran. Any person who is on the list is ineligible to contract with any political subdivision of the State of Tennessee, and any such contract will be considered void under T.C.A. 12-12-110. The list is published on the Tennessee Department of General Services' website at: https://www.tn.gov/content/dam/tn/generalservices/documents/cpo/library/0 po-library/public-information- library/List of persons pursuant to Tenn. Code Ann. 12-12- 106 Iran Divestment Act updated with NY06-07-23.pdf CERTIFICATION By submission of this bid, each bidder and each person signing on behalf of any bidder certifies, and in the case of a joint bid each party thereto certifies as to its own organization, under penalty of perjury, that to the best of its knowledge and belief that each bidder is not on the list created pursuant to T.C.A 12-12-106. Bidder Name: ACTIVE ENERGY SERVICES, LLC Bidder Signature: Rhurd Date: 5/26/26 12 I Page State of Tennessee Non-Boycott of Israel Certification The Bidder certifies that it is not currently engaged in and will not for the duration of the contract engage in a boycott of Israel as defined by Tenn. Code § 12-4-119. This provision shall not apply to contracts with a total value of less than two hundred fifty thousand dollars ($250,000) or to contractors with less than ten (10) employees. According to the law, a boycott of Israel means engaging in refusals to deal, terminating business activities, or other commercial actions that are intended to limit commercial relations with Israel, or companies doing business in or with Israel or authorized by, licensed by, or organized under the laws of the State of Israel to do business, or persons or entities doing business in Israel, when such actions are taken: 1. In compliance with, or adherence to, calls for a boycott of Israel, or 2. In a manner that discriminates on the basis of nationality, national origin, religion, or other unreasonable basis, and is not based on a valid business reason. Tenn. Code § 12-4-119 Signature: Print: RICHARD EVERETT Date: 5/26/26 Phone/Email: 11 I Page POST IN A City of Clarksville License Number CONSPICUOUS Business License and Gross Receipt Tax 106334 PLACE THIS LICENSE EXPIRES ON 05/15/2027 Business Name: ACTIVE ENERGY SERVICES LLC Business ID: 0510329 Location: RICHARD EVERETT State ID: 0104267492 4705 CHAPEL HILL RD SOUTHSIDE, TN 37171 BUSINESS TAX SEAL OF TENNESSSE THE THE CITY OF DEPARTMENT RICHARD EVERETT 4705 CHAPEL HILL RD DEC.1785 SOUTHSIDE, TN 37171 THE LICENSE PERIOD IS JANUARY 1ST TO DECEMBER 31ST (CALENDAR YEAR). YOUR RENEWAL IS DUE BY APRIL 15TH AND MUST BE SUBMITTED NO LATER THAN APRIL 15TH TO AVOID PENALTY AND INTEREST. ALL RETURNS MUST BE FILED ELECTRONICALLY WITH THE STATE OF TENNESSEE Classification: CLASS 4 DEPARTMENT OF REVENUE Date Issued: 04/15/2026 THIS LICENSE DOES NOT PERMIT OPERATION UNLESS PROPERLY ZONED, AND/OR IN COMPLIANCE WITH ALL OTHER APPLICABLE LAWS/RULES. ALSO, AS REQUIRED BY TENN. CODE ANN. § 39-17-1801 ET SEQ, BUSINESSES MUST COMPLY WITH ALL PROVISIONS OF THE Christen Wilcox TENNESSEE NON-SMOKERS PROTECTION ACT. By Chief Financial Officer This License is NOT Transferable License Copy POST IN A City of Clarksville License Number CONSPICUOUS Business License and Gross Receipt Tax 106334 PLACE THIS LICENSE EXPIRES ON 05/15/2027 Business Name: ACTIVE ENERGY SERVICES LLC Business ID: 0510329 Location: RICHARD EVERETT State ID: 0104267492 4705 CHAPEL HILL RD SOUTHSIDE, TN 37171 BUSINESS TAX RICHARD EVERETT 4705 CHAPEL HILL RD SOUTHSIDE, TN 37171 CITY OF CLARKSVILLE THE OF AGRICULTURE COMMERCE Classification: CLASS 4 SEAL TENNESSEE Date Issued: 04/15/2026 DEC.1785 By Christen Wilcox Chief Financial Officer 7796' STATE OF TENNESSEE DEPARTMENT OF REVENUE Resale Authorization January 14, 2026 Letter ID: L1963260352 ACTIVE ENERGY SERVICES, LLC Account ID: 1000032556-SLC 4705 CHAPEL HILL RD Account Type: Sales and Use Tax SOUTHSIDE TN 37171-9104 The above named taxpayer has been granted authority in accordance with Tenn. Code Ann. § 67-6-102 and Tenn. Comp. R. & Regs. 1320-05-01-62 and 1320-05-01-68 to make purchases intended for subsequent resale without payment of sales or use tax. Any merchandise or other taxable item purchased without the payment of tax upon this resale certificate that is used or consumed in any manner by the taxpayer, or is given away, must be reported and the tax paid directly to the Tennessee Department of Revenue. It is a misdemeanor to misuse the certificate of resale for the purpose of obtaining taxable property or services without the payment of the sales or use tax when it is due and such wrongful use is grounds for the Commissioner to revoke the taxpayer's Certificate of Registration. The taxpayer must furnish its supplier(s) at the time of purchase with a copy of the enclosed certificate with the lower portion properly completed. The original certificate should be retained for copy purposes. The supplier must maintain a file copy as evidence of the sales tax exemption. Later purchases do not require the submission of additional copies. The taxpayer must notify the seller in writing if the certificate is no longer valid. David Senegano David Gerregano Commissioner of Revenue Taxpayer Services Division 500 Deaderick Street Nashville, TN 37242 Tel 615-253-0600 www.tn.gov/revenue aL0025 THE STATE STATE OF TENNESSEE AGRICULTURE DEPARTMENT OF REVENUE 1796 Letter ID: L1963260352 ACTIVE ENERGY SERVICES, LLC Effective Date: January 14, 2026 4705 CHAPEL HILL RD Account ID: 1000032556-SLC SOUTHSIDE TN 37171-9104 Account Type: Sales and Use Tax Location ID: 0104267492 Location Address: ACTIVE ENERGY SERVICES, LLC 1300 COLLEGE ST CLARKSVILLE TN 37040-3326 Sales and Use Tax Certificate of Resale The above named taxpayer has been granted authority in accordance with Tenn. Code Arin. § 67-6-102 and Tenn. Comp. R. & Regs. 1320-05-01-62 and 1320-05-01-68 to make purchases intended for subsequent resale without payment of sales or use tax. Any merchandise or other taxable item purchased without the payment of tax upon this resale certificate that is used or consumed in any manner by the taxpayer, or is given away, must be reported and the tax paid directly to the Tennessee Department of Revenue. The supplier must maintain a file copy as evidence of the sales tax exemption. Later purchases do not require the submission of additional copies. Seller's Name Seller's Address (City & State) I, RICHARD EVERETT , as an authorized representative of the taxpayer, certify that the products or services purchased are intended for subsequent resale by the purchaser for the following reason. (X) resale of the tangible personal property, taxable service, taxable amusement, or taxable digital product ( ) rental or leasing of the tangible personal property ( ) a component part of a manufactured, assembled, processed or refined finished product that is for resale Under penalty of perjury, I affirm this to be a true and correct statement. RICHARD EVERETT Alum 1/14/26 Print Name of Authorized Representative Signature of Authorized Representative Date ACORD® DATE (MM/DD/YYYY) CERTIFICATE OF LIABILITY INSURANCE 03/23/2026 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). CONTACT PRODUCER NAME: Commercial Service PHONE Carlson Insurance Group (A/C. No. Ext): (615) 200-7464 (A/C, FAX No): (888) 667-1469 E-MAIL 166 Belinda Pkwy Suite 100 ADDRESS: service@carlsoninsgrp.com INSURER(S) AFFORDING COVERAGE NAIC # Mount Juliet TN 37122 INSURER A: ERIE INSURANCE EXCHANGE 26271 INSURED INSURER B : ERIE INSURANCE P&C COMPANY 26830 Active Energy Services LLC INSURER C: 4705 Chapel Hill Road INSURER D : INSURER E: Southside TN 37171 INSURER F : COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MM/DD/YYYY) (MM/DD/YYYY) LIMITS COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 DAMAGE TO RENTED CLAIMS-MADE OCCUR PREMISES (Ea occurrence) $ 2,000,000 MED EXP (Any one person) $ 5,000 A Q61-0223467 09/10/2025 09/10/2026 PERSONAL & ADV INJURY 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE 4,000,000 POLICY PRO- JECT LOC PRODUCTS- COMP/OP AGG $ 4,000,000 $ OTHER: COMBINED SINGLE LIMIT AUTOMOBILE LIABILITY (Ea accident) $ 1,000,000 ANY AUTO BODILY INJURY (Per person) $ A OWNED SCHEDULED Q09-1040070 09/10/2025 09/10/2026 BODILY INJURY (Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY (Per accident) $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ 5,000,000 A EXCESS LIAB CLAIMS-MADE Q33-1070407 09/10/2025 09/10/2026 AGGREGATE $ DED RETENTION $ $ WORKERS COMPENSATION PER OTH- STATUTE ER AND EMPLOYERS' LIABILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE E.L. EACH ACCIDENT $ 1,000,000 B OFFICER/MEMBER EXCLUDED? N N/A Q93-1000935 09/10/2025 09/10/2026 (Mandatory in NH) E.L. DISEASE - EA EMPLOYEE $ 1,000,000 If yes, describe under DESCRIPTION OF OPERATIONS below E.L. DISEASE - POLICY LIMIT $ 1,000,000 $300,000 RENTED/LEASED EQUIPMENT A Q61-0223467 09/10/2025 09/10/2026 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. State of Tennessee - CPO Risk Manager 312 Rosa L Parks Ave AUTHORIZED REPRESENTATIVE 3rd Floor Central Procurement Office Nashville TN 37243 cari crawford © 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25 (2016/03) The ACORD name and logo are registered marks of ACORD POST IN A City of Clarksville License Number CONSPICUOUS Business License and Gross Receipt Tax 106334 PLACE THIS LICENSE EXPIRES ON 05/15/2027 Business Name: ACTIVE ENERGY SERVICES LLC Business ID: 0510329 Location: RICHARD EVERETT State ID: 0104267492 4705 CHAPEL HILL RD SOUTHSIDE, TN 37171 THEY OF CLARKSVILLE THE BUSINESS TAX OF RICHARD EVERETT SEAL TENNESSEE 4705 CHAPEL HILL RD SOUTHSIDE, TN 37171 DEC.1785 THE LICENSE PERIOD IS JANUARY 1ST TO DECEMBER 31ST (CALENDAR YEAR). YOUR RENEWAL IS DUE BY APRIL 15TH AND MUST BE SUBMITTED NO LATER THAN APRIL 15TH TO AVOID PENALTY AND INTEREST. ALL RETURNS MUST BE FILED Classification: CLASS 4 ELECTRONICALLY WITH THE STATE OF TENNESSEE DEPARTMENT OF REVENUE Date Issued: 04/15/2026 THIS LICENSE DOES NOT PERMIT OPERATION UNLESS PROPERLY ZONED, AND/OR IN COMPLIANCE WITH ALL OTHER APPLICABLE LAWS/RULES. ALSO, AS REQUIRED BY TENN. CODE ANN. § 39-17-1801 ET SEQ, BUSINESSES MUST COMPLY WITH ALL PROVISIONS OF THE By Christen Wilcox TENNESSEE NON-SMOKERS PROTECTION ACT. Chief Financial Officer This License is NOT Transferable License Copy POST IN A City of Clarksville License Number CONSPICUOUS Business License and Gross Receipt Tax 106334 PLACE THIS LICENSE EXPIRES ON 05/15/2027 Business Name: ACTIVE ENERGY SERVICES LLC Business ID: 0510329 Location: RICHARD EVERETT State ID: 0104267492 4705 CHAPEL HILL RD SOUTHSIDE, TN 37171 BUSINESS TAX RICHARD EVERETT 4705 CHAPEL HILL RD SOUTHSIDE, TN 37171 CITY OF CLARKSVILLE THE OF AGRICULTURE COMMERCE Classification: CLASS 4 SEAL TENNESSEE Date Issued: 04/15/2026 DEC.1785 By Christen Wilcox Chief Financial Officer Background Check Acknowledgement Form Contractor is required to meet al TCA 49-5-406, local, state, and federal laws regarding "workers on school properties." The Hickman County Board of Education further requires that no prior felons, drug offenders, or sexual registered offenders work on any school properties. Contractors will be required to wear contractor provided identification when on school premises. The contractor may be asked to provide proof of background check. Signature: Print: RICHARD EVERETT Title: MANAGER Date: 5/26/26 10 I Page The Hickman County Finance Office will be accepting bids for a "Fire Alarm Monitoring/Service Repair and Equipment Replacement." This bid is for a multi-year contract covering fire alarm monitoring/service repair, and equipment replacement for Hickman County Schools. This bid will be system wide for all schools. The bid will be for a period of 3 years with a mutual two-year extension option. This bid will be good for the period of July 1, 2026 - June 30, 2029. All bidders must attach: A conflict-of-interest disclosure form can be obtained at https://ww.hickmank12.org/requestforproposal. Iran Divestment Act Certification Non-Boycott of Israel Certification TN business license A 1-million-dollar liability insurance certificate Workers compensation insurance Business license Background Acknowledgement Form Per TCA 49-5-406, all bidders' employees working on school properties must comply with all local, state, and federal laws. Sealed bids must be mailed or hand-delivered to the Hickman County Finance Office, 114 North Central Avenue, Suite 203, Centerville, TN 37033, and clearly marked on the outside of the envelope "Fire Alarm Monitoring/Service Repair and Equipment Replacement". Bids will be opened on May 26, 2026, at 10:00 a.m. in the Finance Office. The Hickman County Board of Education reserves the right to accept or reject any and all bids or parts of the bids and to waive any informalities that would prevent the acceptance of a better bid. Complete the bid on B (specs) and submit your bid on those forms. Specifications can be found at https://ww.hickmank12.org/requestforproposal. Or by calling 391-729-3391 Ext 3. NOTE: Please use this sheet to enter your bid figures and attach any necessary documents to the back of the bid sheet. SCOPE This bid is for the 2026/2027, 2027/2028, 2028/2029 school years with a mutual two-year extension option provided no increase in charges or costs during the 5 years bid period with an annual renewal contract letter of intent. SPECIFICATIONS Multi-Year Contract Requirements This bid is for a multi-year contract covering fire alarm monitoring, service repair, and equipment replacement for Hickman County Schools. All pricing submitted must remain firm for the entire five-year contract period. If, at any point during the contract term, the awarded vendor increases pricing for any reason, the contract shall be considered null and void, and the entire project will be rebid. 1| Page Annual Fire Alarm Monitoring by School Fire Alarm Monitoring Services This bid covers the annual cost of monthly fire alarm monitoring for all eight (8) Hickman County School buildings. The facilities included in this service are: EHES- East Hickman Elementary School EHIS - East Hickman Intermediate School EHMS - East Hickman Middle School EHHS- East Hickman High School CES- Centerville Elementary School CIS - Centerville Intermediate School HCMS- Hickman County Middle School HCHS- Hickman County High School The awarded vendor shall provide continuous fire alarm monitoring services for each building and shall invoice the district annually for the full year of monthly monitoring services. All monitoring must meet applicable Fire Marshal requirements and comply with all state and local fire safety regulations. Annual Cost of Monthly Fire Alarm Monitoring $ 4,320 00 2 I Page ANNUAL ALARM TESTING and CERTIFICATION SERVICING of ALARM EQUIPMENT and COMPONENTS At all eight schools, to be scheduled and finished by July 15th of each calendar year. This is to include a written check-off report in accordance with NFPA, to be provided for each school location's front office binder. A written hard copy of the report and service ticket should be left with each school's front office and hard copies sent to the Maintenance Director's office. Annual Fire Alarm Testing and Certification Service of Alarm Equipment and Components $ 16,000.00 3 I Page Installation of Communication Converter System for Fire Alarm Panel (One-time charge, applicable if upgrade is selected) Installation Furnish and install a UL-listed communicator and all required accessories, wiring, power supplies, antennas, and mounting hardware. All equipment shall be fully compatible with the existing fire alarm control panel and associated system components. Installation shall be performed in accordance with the manufacturer's instructions and industry best practices. Programming and Testing Program the communicator and associated fire alarm monitoring equipment to ensure proper operation and supervision. Verify successful transmission of all required alarm, supervisory, and trouble signals to the Monitoring Station. Conduct complete functional testing and provide confirmation that the monitoring system is operating correctly and reliably. Compliance All work shall comply with all applicable local, state, and national codes, including but not limited to: NFPA 72 - National Fire Alarm and Signaling Code UL 864- Standard for Control Units and Accessories for Fire Alarm Systems Equipment shall be listed and approved for fire alarm service and monitoring applications. Documentation Provide test results, programming documentation, and verification of Monitoring Station communication upon completion. Coordinate all required inspections, testing, and acceptance documentation with the Authority Having Jurisdiction (AHJ) as applicable. 4 I Page Installation Labor Per Site EHES $ 1,000.00 EHIS $ 1,000 EHMS $ 1,000 EHHS $ 1,000 CES $ 1,000 CIS $ 1,000 HCMS $ 1,000 HCHS $ 1,000 Total Installation Cost $ 8,000 Equipment Cost Per Site EHES $ 450 EHIS $ 45000 EHMS $ 45000 EHHS $ 45000 CES $ 45000 CIS $ 450000 HCMS $ 45000 HCHS $ 450 Total Equipment Cost $ 3,600 51 Page COST of SERVICING REPAIR and/or REPLACEMENT of EQUIPMENT Service call trip charge is limited to one trip charge per trip to the same zip code. Multi trip charges will only be permitted if moving to a second zip code but not to a second location in the same zip code. Our zip codes for the 8 locations are Centerville Buildings 37033: CES, CIS, HCMS, HCHS and Lyles Buildings 37098: EHES, EHIS, EHMS, EHHS. Service Call Trip Charge $ 12500 Hourly rate per tech $ 100 (normal rate) Hourly rate per tech $ 14000 (over-time rate) All parts exceeding $1,000.00 in cost must accompany the vendors' actual cost invoices incurred and attached with to billing invoices to ensure mark-ups are accurate and correct. Invoices without tickets will not be paid. Parts plus percentage of mark-up 15% % 6 I Page Annual Fire Extinguisher Inspections and Servicing This contract will allow for the bidding of the fire extinguishers to be checked off by location in each building and shall provide inspection, serviced by recharge, and/or replaced if beyond container life cycle and shall be annually retagged as prescribed in the Fire Marshals codes. Buildings are to be serviced 100% and accurately count all locations not missing any extinguishers. The service will be for all 11 locations in the school district to include all eight school buildings, HCHS B Building, Central Office Building, and Bus Garage. A hard copy of the checked-off inspections report by location shall be left with each location's front office and a hard copy to be sent to the Maintenance Director's office upon completion. At the bus garage there are spare extinguishers upstairs that are to be inspected, serviced, tagged and recharged and/or replaced as needed. There are extinguishers downstairs in the garage area for bus/vehicles that are annually serviced, tagged and recharged and/or replaced as needed. Location mapping and check-off sheets shall be the responsibility of the bidding vendor and not charged to HCBOE. NOTE: This agreement contract will require that the vendor return during the calendar year at no charge and tag & service any extinguishers that are missed at no cost to the owner, in the event they were not tagged during the inspections and found by the Maintenance and/or the Fire Marshall. Annual inspection fee per extinguisher one time re-tag by location $ 16 00 New extinguisher replacement cost per size $ 15500 Fire extinguisher recharge cost per size $ 60 00 7 I Page Fire Suppression Hoods: Bi-Annual Fire Suppression Hoods Kitchen Hood Suppression System Service Requirements The Hickman County Schools facilities are equipped with kitchen areas that include one or more fire-suppression hoods. The awarded vendor shall provide comprehensive annual servicing of all hood suppression systems in accordance with applicable codes and manufacturer specifications. As part of the annual service, the vendor is required to: 1. Inspect, test, and properly service all hood suppression systems located within each school facility. 2. Install new fusible links on every suppression hood as required on an annual basis. 3. Provide cleanup services in the event that a system discharges during inspection or testing. This includes the full cleanup and removal of any dry chemical agent discharged onto kitchen equipment or surrounding surfaces. All work must be performed by certified technicians and documented through detailed service reports provided to the district upon completion. Inspection Tagging and Compliance Requirements 1. Inspection Tagging Upon completion of each inspection, the awarded vendor shall affix the appropriate inspection tag or sticker to every hood suppression system. The tag must clearly display the date of inspection and any other information required by applicable fire codes. 2. Inspection Scheduling and Compliance All inspections must be performed within the timeframes prescribed by the Fire Marshal and all relevant fire safety codes. Inspections shall be completed on or up to two (2) days prior to the required due date. Under no circumstances may any inspection occur after the required due date. The awarded vendor is fully responsible for tracking and managing all required inspection intervals across all school kitchens. 3. Documentation and Reporting Requirements On the same day each inspection is completed, the vendor shall: 8 I Page Provide a copy of the inspection report directly to the kitchen manager before leaving the site, and Deliver a hard copy of the full inspection report to the Maintenance Director's office. All documentation must be complete, accurate, and compliant with all reporting standards established by the district and governing authorities. Bi-Annual Manual Pull Station Tagging In addition to the annual hood suppression inspections and tagging requirements described above, the awarded vendor shall install a new bi-annual inspection tag on the manual suppression pull device located at each hood system. This tag must clearly indicate the inspection date and comply with all applicable fire safety and Fire Marshal code requirements. The vendor is responsible for ensuring all bi-annual tags remain current and are replaced on schedule. Suppression inspections are to be at the following kitchen locations: CES 240°/UISIT 480 CIS 480°C HCMS 48000 HCHS $ 240 ²/UISIT 480 EHES 480°C EHIS $ 240 48000 EHMS 480 EHHS 480°C EHHS/VOCATIONAL CULINARY ARTS KITCHEN 600°/NIST 1200 Total amount for two (2) Bi-Annual Suppression Hood Inspections per year: $ 5,04000 91 Page ## Table 1 | EHES | $ 100 | | --- | --- | | EHIS | $ 100 | | EHMS | $ 100 | | EHHS | $ 100 | | CES | $ 100 | | CIS | $ 100 | | HCMS | $ 100 | | HCHS | $ 100 | ## Table 2 | EHES | $ $ 200 | | --- | --- | | EHIS | $ 200 $ | | EHMS | $ 200 | | EHHS | $ 200 | | CES | $ 200 | | CIS | $ 200 | | HCMS | $ 200 $ | | HCHS | $ 200 $ | ## Table 3 | CES $ | 220 | | --- | --- | | CIS $ | 220 | | HCMS | $ 220 $ | | HCHS | $ $ 220 | | EHES | $ 220 | | EHIS | $ 220 220 | | EHMS | $ 220 | | EHHS | $ 440 2 systems | ## Table 4 | Print: | Tony Mallini | | --- | --- | | - Date: | 5-20-26 | ## Table 5 | Bidder Name: | State Systems, INC Tony Mallin, | | --- | --- | | Bidder Signature: | 7 Mul | | Date: | 5/20/26 | ## Table 6 | CONTACT NAME: | | | | --- | --- | --- | | PHONE (A/C. No. Ext): | | FAX (A/C, No): | | E-MAIL ADDRESS: | | | ## Table 7 | | | | | --- | --- | --- | | | INSURER(S) AFFORDING COVERAGE | NAIC # | | INSURER A: | Hudson Excess Insurance Company | 14484 | | INSURER B : | The Travelers Indemnity Company | 25658 | | INSURER C : | The Charter Oak Fire Insurance Company | 25615 | | INSURER D : | Travelers Property Casualty Company of America | 25674 | | INSURER E : | Westchester Surplus Lines Insurance Co | 10172 | | INSURER F : | | | ## Table 8 | LIMITS | | | --- | --- | | EACH OCCURRENCE | $ 1,000,000 | | DAMAGE TO RENTED PREMISES (Ea occurrence) | $ 500,000 | | MED EXP (Any one person) | $ 10,000 | | PERSONAL & ADV INJURY | $ 1,000,000 | | GENERAL AGGREGATE | $ 5,000,000 | | PRODUCTS-COMP/OP AGG | $ 2,000,000 | | | $ | | COMBINED SINGLE LIMIT (Ea accident) | $ 1,000,000 | | BODILY INJURY (Per person) | $ XXXXXXX | | BODILY INJURY (Per accident) | $ XXXXXXX | | PROPERTY DAMAGE (Per accident) | $ XXXXXXX | | | $ XXXXXXX | | EACH OCCURRENCE | $ 5,000,000 | | AGGREGATE | $ 5,000,000 | | | $ XXXXXXX | | [X] PER OTH- STATUTE ER | | | E.L. EACH ACCIDENT | $ 1,000,000 | | E.L. DISEASE- EA EMPLOYEE | $ 1,000,000 | | E.L. DISEASE- POLICY LIMIT | $ 1,000,000 | | Limits: Included/$1M Limits: $250K Fac Occ $5M ! A.gg $5M | | ## Table 9 | INSR LTR | TYPE OF INSURANCE | ADDL INSD | SUBR WVD | POLICY NUMBER | POLICY EFF (MM/DD/YYYY) | POLICY EXP (MM/DD/YYYY) | | --- | --- | --- | --- | --- | --- | --- | | A | [X] [X] [X] COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: PRO- POLICY JECT LOC OTHER: | N | N | ALM10130-00 | 2/7/2026 | 8/1/2026 | | B | [X] AUTOMOBILE LIABILITY ANY AUTO OWNED SCHEDULED AUTOS ONLY AUTOS HIRED NON-OWNED AUTOS ONLY AUTOS ONLY | N | N | DT-810-A8126919-IND-26 | 2/7/2026 | 2/7/2027 | | A | [X] [X] [X] UMBRELLA LIAB OCCUR EXCESS LIAB CLAIMS-MADE DED RETENTION $ 10,000 | N | N | ALMU10056-00 | 2/7/2026 | 8/1/2026 | | C | WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER-EXCLUDED? N (Mandatory In NH) If yes, describe under DESCRIPTION OF OPERATIONS below | N/A | N | UB-A8090273-26-26-G | 2/7/2026 | 2/7/2027 | | A D E | Prof/Poll Leased/Rented Equip Fress | N | N | ALM10130-00 QT-630-A8150089-TIL-26 G4878947A 001 | 2/7/2026 2/7/2026 2/7/2026 | 8/1/2026 2/7/2027 8/1/2026 | ## Table 10 | Service Call Trip Charge | $ 100.00 | | | --- | --- | --- | | Hourly rate per tech $ | 140.00 | (normal rate) | | Hourly rate per tech $ | 210.00 | (over-time rate) | ## Table 11 | Print: | Jennifer McMullin | | --- | --- | | Title: | Special Hazards, Alarm & Detection Sales | | Date: | 5/22/2026 | ## Table 12 | Company: | American Fire Protection Group | | --- | --- | | Address: | 155 North Conalco Drive Jackson, TN 38301 | | Company Phone: | 731-424-0310 | | Inspector: | Cody Holland 2055 TN Portable Fire Ext | | Date of Work: | | | Frequency: | Annual | ## Table 13 | Description: | Fire Extinguishers | | --- | --- | | Work Order: | | ## Table 14 | Zone: 1 | | | | | | | | | | | | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | | Tag | Serial Number | Model | Size | Type | Location | La Servi | ext Service | Frequency | Inspection | Comments | | 1 | C-99119847 | SimplexGrinnell (2017) AA10s | 10# | ABC | Right dock entrance, breakroom | yı 024 | Hydro 2030 | Annual | Pass | | | 2 | C9911988 | SimplexGrinnell (2017) AA10s | 10# | ABC | Pole #1 in from f breaknom | 6)20. | Hydro 2030 | Annual | Pass | | | 3 | I51719087 | Badger (2025) ADV-10MP-1 | 10# | ABC | 2nd pole throms | New 2025 | 6 yr 2031 | Annual | Pass | | | 4 | C-99119899 | SimplexGrinnell (2017) AA10s | 10# | ABC | Bac wan behind poy dercoat. | 6 yr 2024 | Hydro 2030 | Annual | Pass | | | 5 | H22617059 | Badger (2023) ADV-10 | 10# | ABC | 3rd pole down in front of office | New 2023 | 6 yr 2029 | Annual | Pass | | | 6 | C-99119836 | SimplexGrinnell (2017) AA10S | 10# | ABC | 2nd door by loading dock | 6 yr 2024 | Hydro 2030 | Annual | Pass | | | 7 | H22617054 | Badger (2023) ADV-10 | 10# | ABC | Inside office | New 2023 | 6 yr 2029 | Annual | Pass | | | 8 | K-883213 | Ansul (2011) AA105 | 10# | ABC | Loading area | New 2018 | 6 yr 2024 | Annual | Fail | 6yr due | | 9 | C-99119841 | SimplexGrinnell (2017) AA10S | 10# | ABC | Middle pole in loading area | 6 yr 2024 | Hydro 2030 | Annual | Pass | | | 10 | C-99119853 | SimplexGrinnell (2017) AA10S | 10# | ABC | Exit door by dock | 6 yr 2024 | Hydro 2030 | Annual | Pass | | | 11 | E-83203601 | Sentry (2018) AA10S | 10# | ABC | Pole 7 in front of dock | 6 yr 2024 | Hydro 2030 | Annual | Pass | | | 12 | H-09109074 | Sentry (2022) AA10S | 10# | ABC | Pole by welding area, beside rack | 6 yr 2024 | Hydro 2030 | Annual | Pass | | | 13 | C-99119898 | SimplexGrinnell (2017) AA10S | 10# | ABC | Back wall welding area #1 | 6 yr 2024 | Hydro 2030 | Annual | Pass | | ## Table 15 | Company: | American Fire Protection Group | | --- | --- | | Address: | 155 North Conalco Drive Jackson, TN 38301 | | Company Phone: | 731-424-0310 | | Inspector: | Cody Holland 50454 TN Fire Alarm | | Date of Work: | 12/4/2025 | | Frequency: | Annual | | Tag: | Green | ## Table 16 | | | | | Power | Supplies | | | | | --- | --- | --- | --- | --- | --- | --- | --- | --- | | Control Unit | Manufacturer: Notifier | | Model Number: Fcps-24s8 | | Location: Nurse station | 2 | | Disconnecting Location: Mech room | | Battery 1 | Voltage: 12 | Amps: 7 | Mfr Year: 2023 | Load Test Battery 1 | VDC: 13.54 | Ah: 5.39 | Charger Voltage: 14.74 | Result of Battery 1 & 2 | | Battery 2 | Voltage: 12 | Amps: 7 | Mfr Year: 2023 | Load Test Battery 2 | VDC: 13.92 | Ah: 4.60 | Charger Voltage: 13.74 | [X] Pass Fail Replaced | ## Table 17 | Description | Visual Inspection | Functional Test | Results | | --- | --- | --- | --- | | Control unit | [X] Yes No | [X] Yes No | [X] Pass Fail N/A | | Lamps / LEDs / LCDs | [X] Yes No | [X] Yes No | [X] Pass Fail N/A | | Fuses | [X] Yes No | [X] Yes No | [X] Pass Fail N/A | | Trouble signals | [X] Yes No | [X] Yes No | [X] Pass Fail N/A | | Disconnect switches | [X] Yes No | [X] Yes No | [X] Pass Fail N/A | | Ground-fault monitoring | [X] Yes No | [X] Yes No | [X] Pass Fail N/A | | Supervision | [X] Yes No | [X] Y | [X] Pass Fail N/A | | Annunciators | [X] Yes No | [X] Ye. No | [X] Pass Fail N/A | | Remote power panels | [X] Yes No | No | [X] Pass Fail N/A | | Other | Yes No | Y No | Pass Fail N/A | ## Table 18 | Description | Visual Inspection | Functional Test | Results | | --- | --- | --- | --- | | Battery condition | [X] Yes No | [X] Yes No | [X] Pass Fail N/A | | Load voltage | [X] Yes No | [X] Yes No | [X] Pass Fail N/A | | Discharge test | [X] Yes No | [X] Yes No | [X] Pass Fail N/A | | Charger test | [X] Yes No | [X] Yes No | [X] Pass Fail N/A | | Remote panel batteries | [X] Yes No | [X] Yes No | [X] Pass Fail N/A | ## Table 19 | Appliance Type | # Installed | # Tested | Test Results | | --- | --- | --- | --- | | Bell(s) | 0 | 0 | [X] Pass Fail N/A | | Horn(s) | 0 | 0 | [X] Pass Fail N/A | | Horn/Strobe(s) | 17 | 17 | [X] Pass Fail N/A | | Mini Horn(s) | 0 | 0 | [X] Pass Fail N/A | | Speaker(s) | 0 | 0 | [X] Pass Fail N/A | | Speaker/Strobe(s) | 0 | 0 | [X] Pass Fail N/A | | Strobe(s) | 0 | 0 | [X] Pass Fail N/A | ## Table 20 | Zone: 1 | | | | | | | | | --- | --- | --- | --- | --- | --- | --- | --- | | Asset Type | Address | Location | Notes | Frequenc y | Last Tested | Test Results | Comments | | TS | | Backflow bottom | | Annual | 12/4/2025 | Pass | | | TS | | Backflow top | | Annual | 12/4/2025 | Pass | | | TS | | Riser room | | Annual | 12/4/2025 | Pass | | | WF | | Riser room | | Annual | 12/4/2025 | Pass | | | WF | | Wet riser | | Annual | 12/4/2025 | Pass | | ## Table 21 | Zone: Main | | | | | | | | | --- | --- | --- | --- | --- | --- | --- | --- | | Asset Type | Address | Location | Notes | Frequenc y | Last Tested | Test Results | Comments | | DH | 00269159 | At rm 108 | | Annual | 12/4/2025 | Pass | | | DH | 00269148 | At rm 118 | | Annual | 12/4/2025 | Pass | | | DH | 00269149 | At rm 118 | | Annual | 12/4/2025 | Pass | | | DH | 00269168 | At mm 203 | | Annual | 12/4/2025 | Pass | | | DH | 00269169 | At rm 203 | | Annual | 12/4/2025 | Pass | | | SD | 00269175 | At rm 207 | | Annu | 12/4/2025 | Pass | | | DH | 00269085 | At rm 309 | | Ann al | /4/2025 | Pass | | | DH | 00269086 | At rm 309 | | nu | /4/2025 | Pass | | | SD | 00269096 | At m 326 | | | 12/4/2025 | Pass | | | DH | 00269097 | At mm 401 | | nual | 12/4/2025 | Pass | | | DH | 00269099 | At rm 401 | | nual | 12/4/2025 | Pass | | | SD | 00269101 | At rm 409 | | Annual | 12/4/2025 | Pass | | | DH | 00269107 | At rm 410 | | Annual | 12/4/2025 | Pass | | | DH | 00269108 | At rm 410 | | Annual | 12/4/2025 | Pass | | | PS | 00269105 | At mm 410 | | Annual | 12/4/2025 | Pass | | | DH | 00269178 | At room 209 | | Annual | 12/4/2025 | Pass | | | DH | 00269179 | At room 209 | | Annual | 12/4/2025 | Pass | | | DH | 00269087 | At room 309 | | Annual | 12/4/2025 | Pass | | | DH | 00269088 | At room 309 | | Annual | 12/4/2025 | Pass | | | SD | 00269076 | By room 219 | | Annual | 12/4/2025 | Pass | | | SD | 00269077 | By room 223 | | Annual | 12/4/2025 | Pass | | | DD | 00269121 | Dining area ceiling | | Annual | 12/4/2025 | Pass | | | DD | 00269122 | Dining area ceiling | | Annual | 12/4/2025 | Pass | | | SD | 00269186 | Dining rm | | Annual | 12/4/2025 | Pass | | | [X] SD | 00269188 | Dining rm | | Annual | 12/4/2025 | Pass | | | DD | 00269126 | Dining room | | Annual | 12/4/2025 | Pass | | | DD | 00269127 | Dining room | | Annual | 12/4/2025 | Pass | | | PS | 00269189 | Dining room exit | | Annual | 12/4/2025 | Pass | | | [X] HD | 00269190 | Dining room storage | | Annual | 12/4/2025 | Pass | | | PS | 00269161 | Front door | | Annual | 12/4/2025 | Pass | | | HD | 00269187 | In dining room | | Annual | 12/4/2025 | Pass | | | [X] SD | 00269136 | In laundry | | Annual | 12/4/2025 | Pass | | | [X] HD | 00269135 | In laundry room | | Annual | 12/4/2025 | Pass | | | DD | 00269144 | In the hall outside of activities, supply room | | Annual | 12/4/2025 | Pass | | | [X] HD | 00269131 | In the kitchen | | Annual | 12/4/2025 | Pass | | | [X] HD | 00269132 | In the kitchen | | Annual | 12/4/2025 | Pass | | | [X] HD | 00269134 | In the kitchen | | Annual | 12/4/2025 | Pass | | | [X] SD | 00269075 | Nurses station 2 | | Annual | 12/4/2025 | Pass | | ## Table 22 | Zone: Main | | | | | | | | | --- | --- | --- | --- | --- | --- | --- | --- | | Asset Type | Address | Location | Notes | Frequenc y | Last Tested | Test Results | Comments | | [X] SD | 00269146 | SD 35 | | Annual | 12/4/2025 | Pass | | | [X] SD | 00269142 | SD 37 | | Annual | 12/4/2025 | Pass | | | [X] SD | 00269139 | SD 39 | | Annual | 12/4/2025 | Pass | | | [X] SD | 00269119 | SD 41 | | Annual | 12/4/2025 | Pass | | | [X] SD | 00269130 | SD 43 | | Annual | 12/4/2025 | Pass | | | [X] SD | 00269125 | SD 44 | | Annual | 12/4/2025 | Pass | | | [X] SD | 00269129 | SD 46 | | Annual | 12/4/2025 | Pass | | | [X] PS | 00269112 | Serinity rm | | Annual | 12/4/2025 | Pass | | | [X] SD | 00269120 | Vending machine | | Annual | 12/4/2025 | Pass | | ## Table 23 | | Contact | Time | | --- | --- | --- | | Monitoring organization: | AFPG | 10:00 | | Building management: | Maintenance | 10:00 | ## Table 24 | Date: | 12/4/2025 | | --- | --- | | Time: | 10:00 | ## Table 25 | Company: | American Fire Protection Group | | --- | --- | | Address: | 155 North Conalco Drive Jackson, TN 38301 | | Company Phone: | 731-424-0310 | | Inspector: | Brian Johnson 1960 Port/Fixed Ext. | | Date of Work: | 9/16/2025 | | Frequency: | Annual | | Tag: | Green | ## Table 26 | Title | Maintenance | | --- | --- | | Date | 9/16/2025 | | Inspected By | Brian Johnson | ## Table 27 | Inspector License: | 1960 Port/Fixed Ext. | | --- | --- | | Date of Work | 9/16/2025 | | Observations | | ## Table 28 | Signature: | | | --- | --- | | Print: | RICHARD EVERETT | | Date: | 5/26/26 | | Phone/Email: | | ## Table 29 | Business ID: | 0510329 | | --- | --- | | State ID: | 0104267492 | ## Table 30 | Business Name: | ACTIVE ENERGY SERVICES LLC | | --- | --- | | Location: | RICHARD EVERETT 4705 CHAPEL HILL RD SOUTHSIDE, TN 37171 | ## Table 31 | Classification: | CLASS 4 | | --- | --- | | Date Issued: | 04/15/2026 | ## Table 32 | Classification: | CLASS 4 | | --- | --- | | Date Issued: | 04/15/2026 | ## Table 33 | Letter ID: | L1963260352 | | --- | --- | | Account ID: | 1000032556-SLC | | Account Type: | Sales and Use Tax | ## Table 34 | Letter ID: | L1963260352 | | --- | --- | | Effective Date: | January 14, 2026 | | Account ID: | 1000032556-SLC | | Account Type: | Sales and Use Tax | | Location ID: | 0104267492 | | Location Address: | | ## Table 35 | CONTACT NAME: Commercial Service | | | --- | --- | | PHONE (A/C. No. Ext): (615) 200-7464 | (A/C, FAX No): (888) 667-1469 | | E-MAIL ADDRESS: service@carlsoninsgrp.com | | ## Table 36 | | INSURER(S) AFFORDING COVERAGE | NAIC # | | --- | --- | --- | | INSURER A: | ERIE INSURANCE EXCHANGE | 26271 | | INSURER B : | ERIE INSURANCE P&C COMPANY | 26830 | | INSURER C: | | | | INSURER D : | | | | INSURER E: | | | | INSURER F : | | | ## Table 37 | LIMITS | | | --- | --- | | EACH OCCURRENCE | $ 2,000,000 | | DAMAGE TO RENTED PREMISES (Ea occurrence) | $ 2,000,000 | | MED EXP (Any one person) | $ 5,000 | | PERSONAL & ADV INJURY | 2,000,000 | | GENERAL AGGREGATE | 4,000,000 | | PRODUCTS- COMP/OP AGG | $ 4,000,000 | | | $ | | COMBINED SINGLE LIMIT (Ea accident) | $ 1,000,000 | | BODILY INJURY (Per person) | $ | | BODILY INJURY (Per accident) | $ | | PROPERTY DAMAGE (Per accident) | $ | | | $ | | EACH OCCURRENCE | $ 5,000,000 | | AGGREGATE | $ | | | $ | | [X] PER OTH- STATUTE ER | | | E.L. EACH ACCIDENT | $ 1,000,000 | | E.L. DISEASE - EA EMPLOYEE | $ 1,000,000 | | E.L. DISEASE - POLICY LIMIT | $ 1,000,000 | | | $300,000 | ## Table 38 | INSR LTR | TYPE OF INSURANCE | ADDL INSD | SUBR WVD | POLICY NUMBER | POLICY EFF (MM/DD/YYYY) | POLICY EXP (MM/DD/YYYY) | | --- | --- | --- | --- | --- | --- | --- | | A | [X] [X] [X] COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: PRO- POLICY JECT LOC OTHER: | | | Q61-0223467 | 09/10/2025 | 09/10/2026 | | A | [X] [X] [X] AUTOMOBILE LIABILITY ANY AUTO OWNED SCHEDULED AUTOS ONLY AUTOS HIRED NON-OWNED AUTOS ONLY AUTOS ONLY | | | Q09-1040070 | 09/10/2025 | 09/10/2026 | | A | [X] [X] UMBRELLA LIAB OCCUR EXCESS LIAB CLAIMS-MADE DED RETENTION $ | | | Q33-1070407 | 09/10/2025 | 09/10/2026 | | B | WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? N (Mandatory in NH) If yes, describe under DESCRIPTION OF OPERATIONS below | N/A | | Q93-1000935 | 09/10/2025 | 09/10/2026 | | A | RENTED/LEASED EQUIPMENT | | | Q61-0223467 | 09/10/2025 | 09/10/2026 | ## Table 39 | Business ID: | 0510329 | | --- | --- | | State ID: | 0104267492 | ## Table 40 | Classification: | CLASS 4 | | --- | --- | | Date Issued: | 04/15/2026 | ## Table 41 | Classification: | CLASS 4 | | --- | --- | | Date Issued: | 04/15/2026 | ## Table 42 | Print: | RICHARD EVERETT | | --- | --- | | Title: | MANAGER | | Date: | 5/26/26 | ## Table 43 | EHES | $ 1,000.00 | | --- | --- | | EHIS | $ 1,000 | | EHMS | $ 1,000 | | EHHS | $ 1,000 | | CES | $ 1,000 | | CIS | $ 1,000 | | HCMS | $ 1,000 | | HCHS | $ 1,000 | ## Table 44 | EHES | $ 450 | | --- | --- | | EHIS | $ 45000 | | EHMS | $ 45000 | | EHHS | $ 45000 | | CES | $ 45000 | | CIS | $ 450000 | | HCMS | $ 45000 | | HCHS | $ 450 | ## Table 45 | Service Call Trip Charge | $ 12500 | | | --- | --- | --- | | Hourly rate per tech $ | 100 | (normal rate) | | Hourly rate per tech $ | 14000 | (over-time rate) | ## Table 46 | CES | 240°/UISIT 480 | | --- | --- | | CIS | 480°C | | HCMS | 48000 | | HCHS | $ 240 ²/UISIT 480 | | EHES | 480°C | | EHIS | $ 240 48000 | | EHMS | 480 | | EHHS | 480°C |